Discharge Rod With Non Linear Carbon Discharge Rod
Non Linear Carbon Discharge Resistor Type Discharge Rods are used to discharge dead system having limited fault levels and also to discharge the static & induced charges in the dead system or equipment, particularly in transmission lines, cables, transformers, reactors, large bus bar systems, switch-gears etc. The earthing lead is made up of special highly flexible braided copper cable with transparent sheath. Copper Hook of 4" dia of 1/2" thick copper rod & Earth End Clamp of special alloy are provided.
MAIN INSULATION : 'F' Class to IS, BS & IEC Specifications
For Dimensions of Insulated Rods please refer Specifications of Insulated Sticks in the beginning of Electrical Safety Equipment Section.
ACCESSORIES
Discharge Head fitted in the Discharge Rod
Extension handles to extend the length
4" Dia Copper Hook for Bus Bars
Special Waterproof carrying cases
Theory for Controlled Discharging
When discharging inductive apparatus (transformers, reactors etc.) controlled discharging must be used. We provide non linear carbon discharge resistor for this purpose which prevents the lightning impulses appearing across the equipment being discharged. While discharging inductive loads the emf induced across the object is directly proportional to rate of change of flux i.e.
E.m.f. Induced alpha
Ld
ø/dt
Since L (inductance) is usually large and the discharging takes place in microseconds, a huge impulse voltage resembling a 1.2/50üsec pulse appears across the object (a typical waveform is shown in Fig), thus subjecting the equipment under discharging to a lightning impulse voltage.
To overcome this non linear carbon discharge resistor is employed. The reverse temperature coefficient of carbon facilitates controlled discharging. As the current flows through the carbon resistance, this increases the temperature and by virtue of reverse temperature coefficient, the resistance falls. Therefore as the current is flowing, voltage is reducing and since resistance is also reducing a controlled discharging takes place
Drop Out (DO) Fuse Operating Rods
The DO Fuse operating rods has and innovative design for fitting, removing & changing Drop Out Fuses. The DO Fuse Operating Rods has a spring loaded Fuse Jaw which accepts the DO fuses easily and ensures that it does not fall while fitting or removing. The entire operation is carried out from ground level comfortably.
This method saves considerable amount of time and effort for fuse replacement and provides extremely safe procedure as compared to the conventional procedures.
Other Products in 'Electrical Testing and Electrical Safety Equipment' category
Insulated Operating Sticks
High Voltage Detectors
Vacuum Circuit Breaker Bottle Test Sets
Phasing Out Sticks
High Voltage AC & DC Testing Kits
Primary Current Injection Test Sets
View all products(9)
<< Back
Contact Details
TECHNOLOGY PRODUCTS
114, Udyog Vihar, Phase-IV,Gurgaon - 122015, Haryana, India
Phone:
91-124-4014527/2340601/2340963/4014527
Fax:
91-124-2340963/4014527
Send Mail
Send SMS
Key Personnel
Mr. Raghbindra Singh (Manager)
Mobile:
+919810538114, +919818845710
Copyright © 2011-12 by TECHNOLOGY PRODUCTS All Rights Reserved.